Seattle and the Puget Sound industrial areasLicensed and insured(425) 790-3315

Seattle Mezzanine Installation (425) 790-3315 Request a quote

Parts · Stairs, rails and gates

Mezzanine Stairs, Guardrail and Safety Gates in Seattle

We supply and install mezzanine stairs, guardrail, handrails and safety gates in Seattle, laid out to the Seattle Building Code and to Washington's own WAC rules for workplaces. Every open edge gets rail, every pallet drop zone gets a gate, and every new stair gets the rails both rulebooks ask for.

Green steel stair with yellow handrails on both sides climbing to a braced mezzanine deck

Which Rules Cover Mezzanine Stairs, Rails and Gates in Seattle?

Two sets of rules apply, and we build to both. The Seattle Building Code, Chapter 10, covers guards, handrails and stairs, and SDCI checks them in plan review and at inspection. Washington's WAC rules cover the same edges and stairs as a workplace, and L&I's Division of Occupational Safety and Health (DOSH) enforces them for your employees. Their numbers differ, so this page keeps them in separate sections.

Rails and gates are drawn with the frame for every mezzanine installation in Seattle job. Stairs are part of the structure SBC 1613.1 designs for earthquake motions, as our seismic design page explains. The Seattle permit guide covers the rest of the code path, and the cost guide shows how stairs and gates move the price.

What Does the Seattle Building Code Require for Guards and Stairs?

SBC 1015.2 puts guards along open-sided walking surfaces, mezzanines included, when the floor or grade below sits more than 30 inches down, measured anywhere in the 36 inches nearest the open side. Those guards rise at least 42 inches (SBC 1015.3). Their openings must stop a 4-inch sphere, with 21-inch allowances at equipment access and in non-public F, H and S spaces (SBC 1015.4). Each stair flight takes a handrail on both sides, set 34 to 38 inches above the nosings.

Seattle Building Code Numbers for Mezzanine Access2021 Seattle Building Code, Chapter 10. SDCI plan review decides your project.
ItemSeattle Building CodeSection
Where guards startDrop of more than 30 in, measured within 36 in of the open side1015.2
Guard height42 in minimum1015.3
Guard openingsNo 4 in sphere passes1015.4
Openings at equipment access, and in non-public F, H and S areasNo 21 in sphere passes1015.4, exceptions 3 and 4
HandrailsOn each side of a stair flight1011.11
Handrail height34 to 38 in above the nosings1014.2.1
Risers4 in minimum, 7 in maximum1011.5.2
Treads11 in minimum1011.5.2
Headroom80 in minimum1011.3
Alternating tread devicesFrom a mezzanine of 250 sq ft or less serving five people or fewer, in Groups F, H and S1011.14

In Group F buildings, the guard on an exit access stair that serves fewer than three stories and is closed to the public can have its top serve as the handrail, set between 34 and 38 inches (SBC 1015.3, exception 7).

Green steel stair with yellow rails that climbs to a landing, turns and continues up to a mezzanine deck
Illustration: a green steel stair turning at a square landing on its way up to a mezzanine.

What Are Washington State Guardrail Requirements for a Mezzanine?

Washington sets guardrail sizes in its unified fall protection chapter, WAC 296-880-40005. The top rail sits 39 to 45 inches above the walking surface, with an intermediate rail halfway down. Pipe rails use at least 1.5-inch nominal OD pipe, and angle rails use 2 x 2 x 3/8-inch steel angles or a shape of equal strength. Posts stand no more than 8 feet apart. The top rail takes 200 pounds without dropping below 39 inches.

Washington Guardrail and Toeboard SpecsWAC 296-880-40005 and 296-880-20005.
PartWashington rule
Top rail39 to 45 in above the walking surface
Intermediate railHalfway between the top rail and the floor
Pipe railsAt least 1.5 in nominal OD, posts no more than 8 ft on centers
Steel angle rails2 x 2 x 3/8 in angles or equal, posts no more than 8 ft on centers
Strength200 lb applied within 2 in of the top edge, outward or downward
Under that loadTop edge stays at 39 in or higher
Toeboard height3.5 in minimum
Toeboard openings and gapOpenings no larger than 1 in; no more than 1/4 in above the deck

A toeboard is required wherever people can pass below the open side, machinery moves, or falling material could strike equipment (WAC 296-880-20005). Where stock is piled higher than the toeboard, panels or screening run up to the mid rail or the top rail. Rails that take hits from trucking or material handling need heavier stock, closer posts or bracing.

How Does WAC Fall Protection Apply on a Mezzanine?

Under WAC 296-880-20005, an employer protects employees who face a fall of 4 feet or more to a lower level. On a mezzanine that means a standard guardrail on every open side, except at the entrance to a stair, ramp or ladder. Where fall hazards reach 10 feet or more, WAC 296-880-10020 asks for a written fall protection work plan. No plan is required where a guardrail system eliminates the hazard, so rail on every open edge settles it.

Federal OSHA uses the same 4-foot trigger, but DOSH enforces Washington's own WAC text for most private workplaces in the state. While the frame goes up, WAC 296-880-30005 sets fall protection at 10 feet for steel erection, and at 4 feet once the work moves onto a deck or floor.

Which Mezzanine Safety Gate Fits a Seattle Drop Zone?

A two-gate pallet gate fits most Seattle drop zones, because the edge never stands open while pallets go on or off. Washington's rule explains why. When a guardrail must come off for a task, someone has to stay at that spot until it is replaced, and their only duty is to warn others while wearing fall arrest or restraint (WAC 296-880-20005). A gate that closes its deck side before the outer side opens keeps the rail line whole, so no rail comes off. That last point is our design reasoning, not wording from the rule.

If a forklift cannot reach the edge, a mezzanine lift can take the place of a drop zone.

Pallet drop bay at a deck edge closed by yellow gates, two pallets of cartons waiting inside
Illustration: two yellow gates at a pallet drop zone, the outer gate raised and a pallet in the bay.

What Pallet Gate Styles Do We Supply and Install?

We supply and install pivot, dual-swing, sliding, rolling and swing pallet gates in Seattle, plus gates fitted with a beacon. Choose by the width of the opening, how the forklift approaches and how often loads move. Pivot and dual-swing gates keep one side closed at all times. Sliding and rolling gates clear wide openings without swinging into the aisle. Each gate goes in with the guardrail around it.

  • Pivot and dual-swing gates: the deck side closes before the loading side opens.
  • Sliding gates: a mesh panel runs along a track to clear a wide bay.
  • Rolling gates: the gate rolls back on wheels from the loading edge.
  • Swing gates: simple access, run by a written procedure.
  • Beacon gates: an amber light draws eyes to the loading edge.

See every style beside decks and lifts in our mezzanine options gallery.

Yellow mesh gate that slides along its track at a deck loading opening, cartons on a pallet nearby
Illustration: a yellow sliding mesh pallet gate pulled open along its track.

What Goes at Ladder and Stair Openings on a Mezzanine?

Washington asks for a swinging gate or an offset at ladderway and platform openings. WAC 296-880-20005 guards those openings with standard guardrail and toeboards on every exposed side, leaving a passage at the entrance. The passage is "either provided with a swinging gate or so offset that a person cannot walk directly into the hole." We mark each opening, and its gate or offset, on the layout.

Self-closing swing gates at stair heads and ladder tops are a common way to meet it.

Steel fixed ladder rising to a platform, a yellow self-closing gate across the top
Illustration: a fixed ladder topping out at a small platform behind a yellow self-closing gate.

What Is the Washington State Handrail Height on a Stair?

Washington sets handrails at 30 to 38 inches (WAC 296-24-74015). Stair rail systems installed on or after October 1, 2020 rise at least 42 inches from the front edge of the tread to the top rail. Those two heights cannot meet, so the rule says: "Handrails and stair rails constructed after the effective date above must be separate". Only stair rails built before that date may double as a handrail, at 36 to 38 inches.

Washington Stair Rules for MezzaninesWAC 296-24-74005, 296-24-74010 and 296-24-74015.
ItemWashington ruleWAC
Standard stair angle30 to 50 degrees from horizontal296-24-74010
Riser height9.5 in maximum296-24-74010
Tread depth9.5 in minimum296-24-74010
Width22 in minimum between vertical barriers296-24-74010
Headroom6 ft 8 in above any tread296-24-74005
LandingsAt least the stair width, and 30 in deep296-24-74005
Stair strengthFive times the normal live load, never less than 1,000 lb at any point296-24-74005
Handrails30 to 38 in high, 2.25 in finger clearance296-24-74015
Stair rails (from Oct 1, 2020)42 in minimum, separate from the handrail296-24-74015
Stair rail openings19 in maximum at the least dimension296-24-74015

Standard stairs are required where people travel between levels regularly and routinely, once a week or more, including to equipment platforms. Ship, spiral and alternating tread-type stairs are allowed only when the employer can show standard stairs are not feasible (WAC 296-24-74005).

Steep ship stair with yellow rails on both sides climbing to a mezzanine deck
Illustration: a steep galvanised ship stair with handrails up to a small platform.

What Does a Mezzanine Access Project Include?

For stairs, rails and gates we draw each stair and landing, each run of guardrail with its mid rail and toeboard, and the gate at every drop zone and ladder opening. The order is placed with us, and our own installers put the structure up. We measure the room, settle the layout and loads with you, and coordinate the sealed drawings and the permit with the Seattle Department of Construction and Inspections. The same team takes it from the first site visit to the final inspection.

  • Site visit: clear height, column lines, slab, doors and forklift routes.
  • Layout and loads: deck size, stair and gate positions, and the design load for the use.
  • Drawings and permit: plans sealed by a Washington-licensed engineer, filed with the building department.
  • Supply: the columns, beams, decking, stairs, rails and gates, plus a lift when the plan calls for one, delivered to your dock.
  • Install and sign-off: our crew erects it, anchors it and walks the inspector through it.

Sources, read November 2026: Seattle Building Code 2021, Chapter 10 (means of egress) · Seattle Building Code 2021, Chapter 16 (loads and Section 1613 earthquake design) · Chapter 296-880 WAC, Unified safety standards for fall protection · WAC 296-24-73502 · WAC 296-24-74005 · WAC 296-24-74010 · WAC 296-24-74015 · OSHA, Washington State Plan · OSHA 29 CFR 1910.28 · OSHA 29 CFR 1910.29

01Questions

Seattle Stair, Guardrail and Gate Questions

How high does mezzanine guardrail need to be in Seattle?

The Seattle Building Code calls for guards at least 42 inches high wherever the drop beside an open side exceeds 30 inches (SBC 1015.2, 1015.3). Washington's workplace rule sets the top rail at 39 to 45 inches (WAC 296-880-40005). We set the height so both are met.

Source: SBC 1015.3; WAC 296-880-40005

Do new mezzanine stairs in Seattle need a separate handrail and stair rail?

Yes, on stairs your employees use. WAC 296-24-74015 sets handrails at 30 to 38 inches and new stair rails at 42 inches or more, and it states: "Handrails and stair rails constructed after the effective date above must be separate". That date is October 1, 2020.

Source: WAC 296-24-74015

What happens when a rail section comes off for loading on a Seattle mezzanine?

Washington requires a person to stay at the opening until the rail goes back. Under WAC 296-880-20005, that person's only job is to warn others, and they wear fall arrest or restraint. A two-gate pallet gate avoids removing rail at all.

Source: WAC 296-880-20005

Does a Seattle mezzanine need a written fall protection work plan?

Not where guardrails remove the fall hazard. WAC 296-880-10020 asks for a written plan where fall hazards of 10 feet or more exist, and exempts any spot where a guardrail system eliminates the hazard. Rail on every open edge is the simple route.

Source: WAC 296-880-10020

02Request for quote

Ask for a Written Quote

Tell us where the building is, how much clear height you have and what the deck has to carry. A local installer reviews it, asks what is missing and sends a written quote for the Seattle-area job.

  1. 1You describe the room, the load and the timing.
  2. 2We check the size against the code that applies at your address.
  3. 3You get a written scope and quote for supply and installation.

Prefer to talk? (425) 790-3315

Large free-standing galvanised steel mezzanine with yellow guardrail and two stairs, shelving of boxes on the deck, seen from above

Add Usable Floor in Your Seattle Building

  • Sized to the load you will put on the deck.
  • Planned for the code that applies at your address.
  • Designed with the engineer for earthquake forces.
CallRequest a quote