Seattle and the Puget Sound industrial areasLicensed and insured(425) 790-3315

Seattle Mezzanine Installation (425) 790-3315 Request a quote

Options · Types, decks, stairs and gates

Mezzanine Options for Seattle Warehouses and Plants

Pick a type and its framing, then a deck surface, stairs, gates and any lift or extra. Everything is ordered through us and installed by our crew, as part of our mezzanine installation in Seattle. Each frame is designed for the city's earthquake code.

One hall holding four steel mezzanine designs: a storage deck, an office deck, an equipment platform and a two-level deck

02Types

Which Mezzanine Type Suits Your Seattle Building?

The work on the deck chooses the type: storage, order picking, offices or machinery. A free-standing steel frame needs no rack or wall for support, so the floor below stays open. A rack- or shelving-supported deck rests on the storage frames below it. A modular deck arrives as a kit of bolted standard parts. A pick module stacks picking levels, often joined by conveyor. In Seattle, each of these counts as a mezzanine under SBC 505.2. Each needs 7 feet of clear height above and below. Inside city limits, all mezzanines in one room may total one-half of its floor area (SBC 505.2.1). A platform that holds only machinery is an equipment platform under SBC 505.3 instead.

03Framing

How Is a Seattle Mezzanine Framed and Braced?

Every frame on this page is designed to resist earthquake motions, together with anything fixed to it (SBC 1613.1). The framing sets the column spacing, the depth of the structure and how the frame resists sideways shaking. Braced bays use diagonal steel between columns. A moment frame stiffens the beam-to-column joints instead, so aisles stay free of braces. The code's tables place each building in a Seismic Design Category. In Category D, E or F, steel follows AISC 341, except where ASCE 7 allows otherwise (SBC 2205.2.1.2). When soil properties are unknown, the code starts from Site Class D (SBC 1613.2.2). Your engineer sets the seismic design and the slab anchorage for your site. Read more on seismic mezzanine design in Seattle.

Framing and Bracing ChoicesOur planning guide. A Washington-licensed engineer sets the spans, bracing and anchorage for your building.
FramingTypical spansSideways bracingBest fit
Bolted cold-formed sectionsShorter baysBraced bays between columnsSmaller decks where extra columns are fine
Hot-rolled beams and columnsLonger, in one or both directionsBraced bays or moment framesFewer columns under a shallow structure
Bar joists or trussesThe widestBraced bays at chosen column linesSpace for light fixtures, sprinkler pipe and ductwork
Moment (rigid) frameSet by the designStiff beam-to-column jointsNo diagonal braces across aisles or forklift paths
Rack- or shelving-supportedThe rack or shelving bayRack frames designed to RMI ANSI/MH 16.1 (SBC 2209.1)Storage and walk deck in one structure

04Deck surface

Which Deck Surface Should Your Mezzanine Get?

Match the surface to what rolls, drops or stands on it. Board laid over corrugated steel deck is a common floor for cartons and light storage. Smooth resin or composite panels suit carts and pallet jacks. Open bar grating keeps light and air moving and lets sprinkler water fall through. Steel plate stands up to hard wear, and concrete on form deck is the heaviest, quietest choice. Washington's workplace rule says every walking surface must carry its maximum intended load (WAC 296-24-73505). Sprinkler and fire questions are settled in SDCI plan review. Compare the surfaces on our mezzanine decking in Seattle page.

05Stairs and ladders

Which Stairs or Ladders Meet Washington Rules?

The right stair depends on how often people go up and what they bring with them. Washington wants standard stairs where people travel between levels as a routine, once a week or more (WAC 296-24-74005). Those stairs sit between 30 and 50 degrees (WAC 296-24-74010). Ship and alternating tread stairs are allowed only where standard stairs are shown not to be feasible. On stairs built since October 1, 2020, the stair rail and the handrail must be separate parts. The stair rail stands at least 42 inches high; the handrail sits at 30 to 38 inches (WAC 296-24-74015). For exit stairs, the Seattle Building Code adds its own riser, tread and handrail rules (SBC 1011). See stairs, railings and gates in Seattle.

06Gates

Which Gates Belong at Your Pallet Zones and Stair Heads?

Every edge where pallets land needs a gate, and ladderway openings need a swinging gate or an offset path. Washington's fall protection rule starts at 4 feet, and open sides get a standard guardrail (WAC 296-880-20005). If a rail section comes off for loading, a worker must stay at the opening. That worker wears fall protection and has one task: warning others. Our choice for pallet zones is a two-gate design: one gate always closes the edge, so no rail is removed. That is our design reading of the rule, and your safety lead confirms it.

07Lifts

When Does a Seattle Mezzanine Need a Lift?

Consider a lift when no forklift can get to the deck edge. It also helps when carts shuttle between levels through each shift. A VRC (vertical reciprocating conveyor) lifts goods from floor to deck, and people take the stairs. A smaller material lift delivers carts of totes to a gated landing. If a forklift does reach the edge, a gated pallet zone may be enough on its own. Every lift has its own gate and guarding, written into your quote. Read more about mezzanine lifts.

08Add-ons

Which Add-Ons Do Seattle Buyers Request?

Buyers most often add an office on the deck and lighting and sprinkler lines below it. Steel for conveyor runs, load signs and guards at column bases come next. In Seattle, every warehouse and storage area needs durable signs showing the design live load (SBC 107.1). So does any other floor designed above 125 psf. The certificate of occupancy waits until those signs are up (SBC 107.2). An office on the deck must respect the openness rule in SBC 505.2.3. Walls stop at 42 inches unless an exception applies. Every add-on is priced in the same written quote as the frame.

Sources, read November 2026: Seattle Building Code 2021, Section 505 · Seattle Building Code 2021, Chapter 1 (permits, documents, load signs) · Seattle Building Code 2021, Chapter 10 (means of egress) · Seattle Building Code 2021, Chapter 16 (loads and Section 1613 earthquake design) · Seattle Building Code 2021, Chapter 22 (steel and storage racks) · WAC 296-24-73505 · WAC 296-24-74005 · WAC 296-24-74010 · WAC 296-24-74015 · Chapter 296-880 WAC, Unified safety standards for fall protection · SDCI, Multifamily and Commercial STFI Checklist · SDCI, Construction Permit: Addition or Alteration

09Questions

Mezzanine Options Questions, Answered

Do you supply the options as well as install them in Seattle?

Yes. We take the order for every option on this page, and our own installers fit it. The list covers frame, deck, stairs, rails, gates, lifts and add-ons. We do not make the steel or seal drawings. A Washington-licensed engineer seals the set, and we coordinate it with the SDCI permit.

Source: SBC 106.5.2

How do I check the lead time for an option in Seattle?

Press the lead-time button on its card, and the reply gives today's lead time for that item. The full schedule also depends on permit review. SDCI says it aims to finish a first review of simple applications in two to three weeks. For complex ones, the goal is eight weeks. That is SDCI's goal, not a promise of ours.

Source: SDCI, Construction Permit: Addition or Alteration

Do the options I pick change the Seattle permit?

Some do. A new mezzanine is structural work, so SDCI reviews full plans instead of issuing a field-inspection permit. Enclosed offices, stairs, lifts and sprinkler changes all appear on those plans. We settle the options first, and then the engineer draws and seals the set.

Source: SDCI STFI checklist; SBC 505.2.3

Does every mezzanine option need seismic bracing in Seattle?

Every option needs earthquake design: the frame and the parts fixed to it are designed for earthquake motions (SBC 1613.1). How the frame resists them varies: braced bays, a moment frame, or rack frames designed to RMI ANSI/MH 16.1. Your engineer sets the bracing and anchorage for your site, so no option skips that step.

Source: SBC 1613.1, 2209.1

10Request for quote

Price an Option or Check Its Lead Time

Tell us where the building is, how much clear height you have and what the deck has to carry. A local installer reviews it, asks what is missing and sends a written quote for the Seattle-area job.

  1. 1You describe the room, the load and the timing.
  2. 2We check the size against the code that applies at your address.
  3. 3You get a written scope and quote for supply and installation.

Prefer to talk? (425) 790-3315

View along a galvanised mezzanine deck beside tall north windows, with yellow guardrail and pallets of cartons

Add Usable Floor in Your Seattle Building

  • Sized to the load you will put on the deck.
  • Planned for the code that applies at your address.
  • Designed with the engineer for earthquake forces.
CallRequest a quote