Seattle and the Puget Sound industrial areasLicensed and insured(425) 790-3315

Seattle Mezzanine Installation (425) 790-3315 Request a quote

Safety guide · WAC 296-24-74015

Why New Washington Stairs Need Two Rails: WAC 296-24 Handrails and Stair Rails on Seattle Mezzanines

On a new mezzanine stair in Washington, the handrail and the stair rail are two separate parts. WAC 296-24-74015 sets them at heights that cannot meet, and it says so in plain words. This guide explains that rule, the other Washington stair numbers, and the Seattle Building Code's own stair rules, kept apart.

Modular office with large windows and timber-look panels on a green steel mezzanine, with a yellow-railed front stair

Why Do New Washington Stairs Need Two Separate Rails?

Because Washington sets the two at heights that cannot overlap. WAC 296-24-74015 puts handrails at "not less than 30 inches (76 cm) and not more than 38 inches (97 cm)." It sets stair rail systems installed on or after October 1, 2020 at "not less than 42 inches (107 cm)." The rule admits that the 42-inch height "intentionally conflicts" with the handrail range. Then it states: "Handrails and stair rails constructed after the effective date above must be separate". So a new stair gets a tall stair rail along each open side and a lower handrail to hold. Our Seattle mezzanine stairs, railings and gates page shows both parts.

Green steel stair with yellow handrails on both sides climbing to a braced mezzanine deck
Illustration: a stair with a tall stair rail and a separate, lower handrail on each side, the layout Washington asks for on new stairs.

What Is the Difference Between a Handrail and a Stair Rail?

A handrail is what you hold, and a stair rail is the barrier along an open side. The handrail steadies you as you climb, so it sits at hand height. The stair rail stops a fall off the open edge of the flight, so it stands taller. WAC 296-24-74015 gives each part its own tests, from height to finger room to openings. Its strength test is a force of at least 200 pounds, pushed down or outward within 2 inches of the top edge. The table lists the Washington figures.

Washington Rules for Handrails and Stair RailsWAC 296-24-74015 (stair rail systems and handrails).
PartWashington ruleWAC 296-24-74015
Handrail height30 to 38 inches(1)
Stair rail height, installed on or after October 1, 2020At least 42 inches, from the front edge of the tread to the top of the top rail(2)(b)
Finger clearance at a handrailAt least 2.25 inches to any other object(4)
Openings in a stair railNone over 19 inches at the least dimension(6)
Strength at the top edgeAt least 200 pounds, down or outward, within 2 inches of the top(9)

Can an Older Stair Rail Still Serve as the Handrail in Washington?

Only where the stair rail went in before October 1, 2020. WAC 296-24-74015 lets a stair rail system from before that date double as the handrail, at 36 to 38 inches. A stair built on or after that date needs the two parts apart. Federal OSHA reads differently. Under 1910.29(f)(1)(iii), the top rail of a stair rail system "may serve as a handrail only when" it is 36 to 38 inches high and meets the handrail rules. The federal date for 42-inch stair rails is January 17, 2017. So a stair that suits the federal text may still not meet Washington's rule. We design new Seattle stairs to the Washington text. When you rework an older stair, we first check which date its rails fall under.

How Does the Deck Guardrail Meet the Stair in Washington?

The deck guardrail runs along every open side and stops at the stair's entrance. WAC 296-880-20005(1)(a) asks for a standard guardrail on all open sides, "except where there is entrance to a ramp, stairway, or ladder." The stair rail then takes over along the open side of the flight. A landing partway up has open sides of its own, and we rail those as well. Washington sizes landings at no less than the stair's width and at least 30 inches deep. Our guide to WAC fall protection at a mezzanine edge covers the deck side in full.

What Stair Dimensions Does Washington Set for a Mezzanine Stair?

A standard stair climbs at 30 to 50 degrees. Each riser is 9.5 inches or less, and each tread 9.5 inches or more. Those figures come from WAC 296-24-74010, which also asks for 22 inches of width or more between vertical barriers. WAC 296-24-74005 adds headroom, landing and strength rules that apply to all stairs. Federal 1910.25(c) uses the same four standard-stair numbers. Washington's date line for its newer stair rules is October 1, 2020.

Washington Stair Rules for a Mezzanine StairWAC 296-24-74005 and 296-24-74010.
ItemWashington ruleSection
Angle30 to 50 degrees from the horizontal296-24-74010
Riser height9.5 inches at most296-24-74010
Tread depth9.5 inches at least296-24-74010
Width22 inches at least, between vertical barriers296-24-74010
Headroom6 ft 8 in or more, from tread to overhead obstruction296-24-74005(2)
LandingsAt least the stair's width, and 30 inches deep296-24-74005(4)
Strength5 times the expected live load, with a 1,000 lb point load as the floor296-24-74005(6)

When Does a Washington Workplace Need a Standard Stair to the Deck?

When people travel between levels as a routine, which Washington pegs at once a week. WAC 296-24-74005(7) calls for standard stairs "when operations necessitate regular and routine (once per week) travel between levels, including access to operating platforms for equipment." Subsection (8) allows spiral, ship or alternating tread stairs only when "the employer can demonstrate that it is not feasible to provide standard stairs." A storage deck that pickers climb daily therefore gets a standard stair. A steep stair is the exception, and the employer must show why. Plan floor space for a full stair from the first layout.

What Does the Seattle Building Code Set for the Same Stair?

Its own stair figures, which SDCI checks in plan review. SBC 1011.5.2 sets riser heights of "7 inches (178 mm) maximum and 4 inches (102 mm) minimum." Rectangular treads are at least 11 inches deep, with listed exceptions. Section 1011.3 asks for headroom of at least 80 inches. Section 1011.11 says flights "shall have handrails on each side." Section 1014.2.1 then sets handrail height at 34 to 38 inches above the tread nosings. These figures govern the building, and they sit beside the WAC figures rather than replacing them.

Seattle Building Code Rules for a Mezzanine Stair2021 Seattle Building Code, Chapter 10 and Table 1607.1.
ItemSeattle Building CodeSection
HeadroomAt least 80 inches1011.3
Riser height4 to 7 inches1011.5.2
Tread depthAt least 11 inches, rectangular treads1011.5.2
HandrailsOn each side of each flight1011.11
Handrail height34 to 38 inches above tread nosings1014.2.1
Alternating tread devicesFrom a mezzanine of 250 sq ft or less serving five or fewer occupants, in Groups F, H and S1011.14
Stair live load100 psf uniform, 300 lb concentratedTable 1607.1

How Do Both Rule Sets Shape One Seattle Mezzanine Stair?

We lay the stair out so it passes each set on its own terms. The building code's riser and tread limits are the tighter pair, so they usually set the stair's run. The handrail goes inside the building code's height window, which also falls inside Washington's. The stair rail on each open side then rises above the handrail to Washington's height for new stairs. The building code lets a guard's top serve as the handrail on some Group F stairs (SBC 1015.3, exception 7). Washington's workplace rule does not allow that on a new stair, so we keep the parts apart.

What Do We Supply for a Seattle Mezzanine Stair?

The stair, its stair rails and handrails, and any landing it needs, fitted by our own crew. We measure the finished deck height and split it into equal risers that suit both rule sets. We check the open sides, where a landing turns the run, and how much floor the stair can take up. The engineer confirms the stair's loads and connections on the sealed drawings. You order the stair with the deck, and our installers set it, rail it and fix it to the frame.

  1. Measure the deck height and the clear floor at the foot of the stair.
  2. Set the riser count, tread depth and any landing.
  3. Place the handrail inside both height windows, and the stair rail above it.
  4. Confirm loads and connections with the engineer.
  5. Install, then walk the stair with the inspector.

Washington Stair Rail Questions, Answered

What is the handrail height for a mezzanine stair in Seattle?

It has to satisfy two rules. Washington's WAC 296-24-74015 allows 30 to 38 inches. The Seattle Building Code, Section 1014.2.1, sets 34 to 38 inches above the tread nosings. We build inside the narrower building code window, which also meets the WAC.

Source: WAC 296-24-74015; 2021 Seattle Building Code, Section 1014.2.1

Can the top of the stair rail be the handrail on a new stair in Seattle?

Not under Washington's workplace rule. WAC 296-24-74015 says handrails and stair rails built after October 1, 2020 must be separate. Only stair rail systems installed before that date may double as the handrail, at 36 to 38 inches.

Source: WAC 296-24-74015

Do Seattle mezzanine stairs need handrails on both sides?

Yes. SBC 1011.11 says flights of stairways shall have handrails on each side. On a new stair, Washington also keeps any stair rail separate from those handrails.

Source: 2021 Seattle Building Code, Section 1011.11; WAC 296-24-74015

Sources, read November 2026: WAC 296-24-74015 · WAC 296-24-74010 · WAC 296-24-74005 · Chapter 296-880 WAC, Unified safety standards for fall protection · OSHA 29 CFR 1910.29 · OSHA 29 CFR 1910.25 · Seattle Building Code 2021, Chapter 10 (means of egress) · Seattle Building Code 2021, Chapter 16 (loads and Section 1613 earthquake design)

Get a Stair Laid Out for Your Seattle Deck

Send the deck height and how much floor you can give the stair. We set the risers, landings and both rails to the WAC and the Seattle code, then deliver the stair and fit it.

CallRequest a quote